In the standard configuration, the KEBA KeContact P30 sends meter values at defined intervals to the backend system, which can be used for statistics and evaluation of consumption performance.
In connection with the use of SIM cards, we recommend deactivating the continuous data transmission of meter readings, as this behaviour generates a high data volume. You can update the configuration of the charging station to send the meter readings as follows:
- Go to the station data sheet (infrastructure/Charging station/station list) of the charging station in your be.ENERGISED instance.
- Navigate to the Settings tab and retrieve the charging station data.
- In the table, search for the configuration value "ClockAlignedDataInterval" and change this value to "0".
- Restart the charging station via the station data sheet.
The change can be reversed using the same procedure.
To force the meter reading transmission, enter the value "1".