This guide explains all steps needed to get a pre-configured Alpitronic HYC 50 station connect to be.ENERGISED.
Instructions
-
Remove ChargePoint sticker and add be.ENERGISED QR-code stickers
-
Remove ChargePoint SIM card and add be.ENERGISED SIM-card
-
Install the charger, and configure the be.ENERGISED endpoint
Detailed step-by-step guide
1. Remove ChargePoint sticker and add be.ENERGISED QR-code sticker
On the charging station there is a sticker that is not used any more, this charger would only be used if the charger is connected to the ChargePoint -CMS.
This activation sticker can be found next to the station specification plate.
Remove this sticker, wipe off any residue with some isopropylalkohol.
Now add the QR-Code stickers close to the connectors. (Either on the fron panel or on the side where the connector is located)
It is really important to put the stickers separate to differentiate between the available connectors. When used by the customer, only the scanned QR-code will initiate the charge on this specific connector.
2. Remove ChargePoint SIM card and add be.ENERGISED SIM-card
Remove the existing SIM-card and insert the M2M SIM card for be.ENERGISED. (Alternatively you can use any SIM-card with public internet access or use the LAN port to connect to a public internet connection)
Please see the following explaination for the SIM card population:
-
Y209 : Service SIM used for Hypercharger Support M2M connection
-
Y210 : Customer SIM, this is the SIM card slot used for the OCPP connection, well insert the KPN SIM card provided in the networking kit in Y210
If a SIM card is used, the APN-settings need to be changed (explained in step 3)
If the public Internet is used (either via SIM or Ethernet) you have to use the public-Endpoint (explained in step 3)
3. Install the charger, and configure the be.ENERGISED endpoint
Follow the installation guide provided for the hardware installation.
-
Network configuration of your laptop
-
An ethernet cable is needed to connect your laptop to the Alpitronic station. The ethernet port on the Alpitronic station is located inside the station on the bottom left corner, closed to the AC main grid connection, the port is marked XF1
-
-
When laptop and station are well wired via the ethernet cable you need to adjust your laptop network settings
-
Go to the Ethernet Network configuration of your laptop and set it to TCP/IPv4 fixed IP :
-
IP address: 192.168.1.101
-
Subnet mask: 255.255.255.0
-
Standard gateway: 192.168.1.1
-
On Windows (may vary based on which windows version your laptop has)
-
go to Ethernet >> Properties
-
select Internet protocol version 4 (TCP/IPv4) and click on Properties
-
Click to select Use the following IP address then edit it :
-
IP address: 192.168.1.101
-
Subnet mask: 255.255.255.0
-
Standard gateway: 192.168.1.1
-
-
Click on OK to save it !!
On Mac (may vary based on which MacOS version your laptop has)
-
go to settings
-
then go to Network
-
Then select Ethernet, then configure IPv4 manually :
-
save (apply)
-
Open a web browser then enter the IP address : 192.168.1.100
-
When connecting to the web interface for the first time, you will be asked to enter a username
and password-
User Name : Contact Support to ask for the "OnRamp" Credentials for your charger
-
Password : Contact Support to ask for the "OnRamp" Credentials for your charger
-
-
-
Then you access to the main menu of the Hypercharger Web UI :
3.2 Go to OCPP and then select the tab “BOOT.INI FILE” and configure as follows
chargePointIdentity: leave configured ID or choose your own one
msgEngineType: json
WebSocketURL: ws://INSTANCE.private.ocpp-broker.com/ocpp/cp/socket/16
Replace “INSTANCE” with your corresponding part of the enpoint usually found in the browser-search-bar when logged in to be.ENERGISED.
Click “Save Configuration”.
3.3 Go back to the landing page and select “NETWORK” and go to the “SIM” tab.
Then go to “APN Configuration”
Leave the SIM Pin empty.
APN name: use the APN name found on the sticker of the provided SIM-card
APN user: use the APN user found on the sticker of the provided SIM-card
APN password: use the APN password found on the sticker of the provided SIM-card
Confirm with “Save Configuration” and restart the charging station by clicking on “RESET” and then “Soft Reset HYC”.
Once re-booted, the charger shows up in your system with the above configured chargePointIdentity.
-